Chemglass CG-2024-10 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Zubehör fürs Wasser Chemglass CG-2024-10 herunter. Chemglass CG-2024-10 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 4
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1
by VELP Scientifica
Instruction Manual
CG-2024-10
Overhead Stirrer
General Information
Before using the unit, please read the following instruction manual carefully.
Do not dispose of this equipment as urban waste, in accordance with EEC directive 2002/96/CE.
This unit must be used for laboratory applications only.
The manufacturer declines all responsibility for any use of the unit that does not comply with these instructions.
This unit has been designed and manufactured in compliance with the following standards:
Safety requirements for electrical equipment for measurement, control and for laboratory use
IEC/EN 61010-1
Electrical equipment for laboratory use
UL 61010-1
General requirement - Canadian electrical code
CAN/CSA-C22.2 No.61010-1
VELP reserves the right to modify the characteristics of its products with the aim to constantly improving their quality.
Safety Regulations
The values indicated on the rating plate of the instrument must correspond to those of the power supply.
Position the instrument on a flat surface, with a distance from the wall of 30 cm (at least).
Fasten the unit to the support rod using the double clamp. Secure the receptacle using the ribbon clamp.
Safe working conditions are ensured only when the accessories described in the dedicated chapter are used.
The working speed set on the instrument must be such as to avoid wobbling and/or splashes.
Do not use the instrument in explosive environment or with dangerous substances.
The unit must not be immerged in water.
It is dangerous to run the unit with the stirring blade turning in free air.
Always place the stirring shaft in the receptacle before turning the unit on.
Do not run the unit with the stirring shaft protruding through the top membrane.
This membrane should be fully closed when the unit is in use.
Contents
1. INTRODUCTION .............................................................................................................................................................. 2
2. ASSEMBLY AND INSTALLATION ................................................................................................................................... 2
2.1 ELECTRICAL CONNECTION ............................................................................................................................................. 2
2.2 START-UP .................................................................................................................................................................... 2
2.3 INFORMATION ABOUT CONSTRUCTION MATERIALS........................................................................................................... 2
3. OPERATING CONTROLS ............................................................................................................................................... 2
3.1 TORQUE INDICATOR ...................................................................................................................................................... 2
3.2 OVERLOAD PROTECTION ............................................................................................................................................... 2
4. MAINTENANCE ............................................................................................................................................................... 3
4.1 CLEANING .................................................................................................................................................................... 3
5. TECHNICAL DATA .......................................................................................................................................................... 3
6. WIRING DIAGRAM .......................................................................................................................................................... 3
7. ACCESSORIES ............................................................................................................................................................... 4
8. WARRANTY ..................................................................................................................................................................... 4
9. DECLARATION OF CONFORMITY ....................................................................................................................... 4
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - CG-2024-10

1 by VELP Scientifica Instruction Manual CG-2024-10 Overhead Stirrer General Information Before using the unit, please read the following in

Seite 2 - 3. Operating controls

2 1. Introduction Overhead stirrers are generally used for laboratory applications where the solubilization, mixing, suspension, emulsioning and h

Seite 3 - 6. Wiring diagram

3 Over Curr Rpm error This error message is displayed if the chuck is accidentally blocked or if the number of revs exceeds the permitted value. Ove

Seite 4 - 8. Warranty

4 7. Accessories Please contact Chemglass Life Sciences for more details about accessories. www.cglifesciences.com 1-800-843-17948. Warranty T

Kommentare zu diesen Handbüchern